Lenze SCD Series User Manual

Page 92

Advertising
background image

89

DNET Par. ID 144 - DEVICENET INPUT ASSEMBLY SELECTION (ACT PARAM. C04):
Select the input assembly, production size, and path for the following I/O connections:
- Polling
- Bit-Strobe
- Change of State
- Cyclic

1 = "50 Basic Overload"

- ODVA SPECIFIED

2 = "51 Extended Overload"

- ODVA SPECIFIED

3 = "52 Basic Motor Ctrl"

- ODVA SPECIFIED

4 = "53 Ext. Motor Ctrl 1"

- ODVA SPECIFIED

5 = "54 Ext. Motor Ctrl 2"

- ODVA SPECIFIED

6 = "70 Basic Speed Ctrl"

- ODVA SPECIFIED

7 = "71 Ext. Speed Ctrl"

- ODVA SPECIFIED

8 = "101 Ext.Speed Ctrl Hz"

- AC TECH specific (same as 71, except speed is in Hz)

9 = "102 Custom Assembly"

- AC TECH specific

10 = "104 Custom Assembly"

- AC TECH specific

11 = "105 Custom Assembly"

- AC TECH specific

INPUT ASSEMBLY DETAILS:

BYTE

BIT 7

BIT 6

BIT 5

BIT 4

BIT 3

BIT 2

BIT 1

BIT 0

0

FAULTED

50 BASIC OVERLOAD/CONTACTOR INPUT ASSEMBLY

BYTE

BIT 7

BIT 6

BIT 5

BIT 4

BIT 3

BIT 2

BIT 1

BIT 0

0

CONTROL

FAULTED

FROM NET.

51 EXTENDED OVERLOAD/CONTACTOR INPUT ASSEMBLY

BYTE

BIT 7

BIT 6

BIT 5

BIT 4

BIT 3

BIT 2

BIT 1

BIT 0

0

RUNNING

FAULTED/

FORWARD

TRIP

52 BASIC MOTOR CONTROL INPUT ASSEMBLY

BYTE

BIT 7

BIT 6

BIT 5

BIT 4

BIT 3

BIT 2

BIT 1

BIT 0

0

CONTROL

READY

RUNNING

FAULTED/

FROM NET.

FORWARD

TRIP

53 EXTENDED MOTOR CONTROL 1 INPUT ASSEMBLY

Advertising