B.6

DESCRIPTION OF DEVICENET

TM

PARAMETERS

Parameter ID 40 to 130 (AC Tech parameters 1 to 90) have been described in detail in Section 15.0 -
DESCRIPTION OF PARAMETERS.

DNET Par. ID 1 - OUTPUT FREQUENCY (READ ONLY): Actual output frequency to motor (0.1
Hz resolution).

DNET Par. ID 2 - OUTPUT VOLTAGE (READ ONLY): Actual output voltage to the motor (1 Volt
resolution).

DNET Par. ID 3 - OUTPUT CURRENT (READ ONLY): Output current to the motor (0.1 Amp
resolution).

DNET Par. ID 4 - ESTIMATED OUTPUT POWER (READ ONLY): In Watts (1 Watt resolution).

DNET Par. ID 5 - INPUT VOLTAGE (READ ONLY): In Volts (1 Volt resolution).

NOTE: DNET Parameters 2, 3, 4, and 5 are estimated and their accuracy depends on the accuracy of
the following parameters:

B.5.11 ACKNOWLEDGE HANDLER OBJECT - CLASS 0x2B

ATTRIBUTE ID ACCESS RULE

NAME

DATA TYPE

VALUE

1

GET

REVISION

UINT

1

2

GET

NUMBER OF

UINT

1

INSTANCES

1

GET / SET

ACKNOWLEDGE TIMER

UINT

1 to 65535 ms

2

GET / SET

RETRY LIMIT

USINT

0 to 255

3

GET

COS PRODUCING

UINT

4

CONN. INSTANCE

INSTANCE 1

ACKNOWLEDGE HANDLER CLASS ATTRIBUTES

INSTANCE 0

SERVICE

SERVICE

CODE

CLASS

INSTANCE

NAME

0x0E

YES

YES

Get_Attribute_Single

0x10

NO

YES

Set_Attribute_Single

ACKNOWLEDGE HANDLER SERVICES