47

P58

KEYPAD AND PROTECTION STATUS

This indicates the status of the buttons on the keypad, and the status of the protective circuitry in the
drive, using the horizontal segments of the LED. An illuminated segment indicates that the
corresponding button is pressed, or the protective circuit is active. See the diagram below:

CHARGE
RELAY

TB-1

TB-12

TB-13A

TB-13B

TB-15

TB-14

TB-13C

FCLIM

Mode

OUTPUT

FAULT

!

"

NOTE: FCLIM is an abbreviation for Fast Current Limit.

P59

TB-30 ANALOG OUTPUT

This displays the level of the analog output signal at TB-30. A reading of 100% indicates that the
output is 10 VDC.

P60

TB-31 ANALOG OUTPUT

This displays the level of the analog output signals at TB-31. A reading of 100% indicates that the
output is 10 VDC.

P85

MOTOR RATED RPM

When using the DeviceNet interface, this must be set to match the nameplate RPM of the motor.

P86

MOTOR RATED CURRENT

When using the DeviceNet interface, this must be set to match the nameplate full load amperage
(FLA) rating of the motor.