52

DISPLAY

DESCRIPTION

br

DC BRAKING: The DC braking circuit is activated.

CL

CURRENT LIMIT: The output current has exceeded the CURRENT LIMIT setting (Parameter 25)

and the drive is reducing the output frequency to reduce the output current. If the drive remains

in CURRENT LIMIT for too long, it can trip into a CURRENT OVERLOAD fault (PF).

Er

ERROR: Invalid data has been entered or an invalid command was attempted.

GE

"GE" will be displayed if an attempt is made to change the OEM default settings when the drive is

operating in the OEM mode (see Parameter 48).

GF

If "GF" is displayed when a RESET OEM is attempted, it indicates that the OEM defaults in the

EPM are corrupted. If "GF" is displayed upon power-up, it indicates that the OEM defaults and

the user settings in the EPM are corrupted. Refer to Section 13.2.

LC

FAULT LOCKOUT: The drive has failed three restart attempts and now requires a manual reset.

SP

START PENDING: "SP" blinks during the interval between restart attempts.

DECEL OVERRIDE (both upper decimal points blinking): The drive has stopped decelerating to

avoid tripping into an HF fault due to regenerative energy from the motor.

STATUS AND WARNING MESSAGES

SPEED SOURCE DISPLAYS

DISPLAY

DESCRIPTION

CP

CONTROL PAD: Speed is set using the

! and " buttons on the front of the drive.

EI

EXTERNAL CURRENT: Speed is controlled by a 4-20 mA signal wired to TB-25 and TB-2

EU

EXTERNAL VOLTAGE: Speed is controlled by a 0-10 VDC signal wired to TB-5 and TB-2.

JG

JOG: The drive is in Jog mode, and the speed is set by Preset Speed #2 (Parameter 32).

dn

DEVICENET: Speed is controlled from the DeviceNet interface.

OP

MOP (Motor Operated Pot): Contacts wired to TB-13B and TB-13C are used to increase and

decrease the drive speed.

Pr1 - Pr7

PRESET SPEEDS #1-7: Speed is set by the indicated Preset Speed (Parameters 31-37).

NOTE: The speed source displays will flash when the speed reference source is changed while the
drive is running to indicate that the new speed reference source is active.