Electrical installation – Lenze EMB934x User Manual

Page 106

Advertising
background image

Electrical installation

Installation according to EMC (installation of a CE−typical drive system)
Fuses and cable cross−sections

5

l

106

EDBMB9340 DE/EN/FR 12.0

5.2

Installation according to EMC (installation of a CE−typical drive system)

The measures described must be carried out to comply with the EMC standards specified.

Control cabinet mounting plate

ƒ

For HF earthing, only use mounting plates with an electrically conductive surface
(e.g. zinc−coated surface).

ƒ

If you use mounting plates with poor conducting surfaces (e.g. painted, anodised,
yellow chromated):
– Remove the paint or coating from the contact surfaces of the mains filter,

regenerative power supply module and shield connections to provide a
large−surface, electrically conductive connection.

ƒ

If you use several mounting plates, connect them with a surface as large as possible
(e.g. by copper bands).

ƒ

Provide a surface contact as large as possible between the regenerative power
supply module, mains filter and the earthed mounting plate.

Control cables

ƒ

The control cables must always be shielded.

ƒ

Connect the shields of the control cables on both sides.

ƒ

If you expect potential differences, install an additional equalising cable.