Electrical installation – Lenze EMB934x User Manual
Page 110
Advertising
![background image](/manuals/566110/110/background.png)
Electrical installation
Regenerative power supply modules EMB9341 and EMB9342
Power connections
l
110
EDBMB9340 DE/EN/FR 12.0
F10
...
F12
39
28
Ax
59
39
28
Ax
59
M
3~
PE
M
3~
PE
E1 39 A1 A2 59
L3
N
PE
L1
L2
F1...F3
9341
9342
Z2.1
Z2.n
PE
PE
+UG
+UG
+UG
-UG
-UG
-UG
K1
F4
F6
F8
F5
F7
F9
Z1
PE U V W
PE U V W
L1
L1
L1
L2
L2
L2
L3
L3
L3
L3’ L2’ L1’ L3.2L2.2L1.2
L1
L1'
L2
L2'
L3
L3'
PE
PE
PE
9340vrm005a
Fig. 5−3
Central supply for DC bus connection of several drives and external mains synchronisation
Z1
Mains filter A
Z2.1 ... Z2.n
Controllers in the drive system
F1...F3
Mains fuse
K1
Main contactor
F4...F9
DC−bus fuses
F10 ... F12
Fuse − mains synchronisation
Advertising