Technical data – Lenze EMB934x User Manual

Page 84

Advertising
background image

Technical data

General data and operating conditions

3

l

84

EDBMB9340 DE/EN/FR 12.0

Environment data

Climatic conditions

Class 3K3 according to EN 60721−3−3 Without condensation, average

relative humidity 5 ... 85 %
Temperature 5 ... 40 °C

Permissible temperature ranges

Transport:

−25 °C ... +70 °C

Storage

−25 °C ... +50 °C

Operation

0 °C ... +50 °C

+40 °C ... +50 °C

with power derating 2 %/°C

Permissible installation height

0 ... 4000 m amsl

1000 m amsl ... 4000 m amsl

with power derating 5 %/1000 m

Vibration resistance

Accelerational stability up to 0.7 g

Germanischer Lloyd, general conditions

Degree of pollution

EN 61800−5−1 degree of pollution 2

Packing

to DIN 4180

l

EMB9341 and EMB9342: dust−free packing

l

EMB9343: shipping package

Enclosure

IP20 (protection against accidental contact to NEMA 250 type 1)

General project planning data

Mounting position

Vertical with power connection at the top

Mounting clearances

100 mm above and below

General electrical data

EMC

The requirements to IEC 61800−3 are complied with when the regenerative
power supply module is installed according to the demands of the CE−typical
drive system

Noise emissions

The limit class C2 to IEC 61800−3 is complied with when the regenerative
power supply module is installed according to the demands of the CE−typical
drive system

Noise immunity

Compliance with the limit values to IEC 61800−3

Insulation resistance

0 ... 2000 m: Overvoltage category III according to EN 61800−5−1
> 2000 ... 4000 m: Overvoltage category II according to EN 61800−5−1

Discharge current to PE

> 3.5 mA; i.e. fixed installation is required; the PE connection must be carried
out to EN 61800−5−1

Permissible mains types

Mains with grounded
neutral (TT/TN)

No restrictions

Mains with isolated
neutral (IT mains)

Not permitted

Mains with grounded
phase conductor

Not permitted

Advertising