Electrical installation – Lenze EMB934x User Manual

Page 113

Advertising
background image

Electrical installation

Regenerative power supply modules EMB9341 and EMB9342

Power connections

5

l

113

EDBMB9340 DE/EN/FR 12.0

Wiring procedure

1. Disengage the two covers of the regenerative power supply module to the front

with a slight pressure and remove them.

2. Mount the fixing brackets for the shield sheet

2:

– Hand−screw nut M5

1 on the PE stud 0.

– Fit fixing bracket for shield sheet

2

– Fit serrated lock washer

3

– Fit PE core with ring cable lug

4

– Fit washer

5

– Fit spring washer

6

– Screw on nut M5

7 and tighten with 3.4 Nm (30 lb−in)

3. Use two screws M4 to screw the shield sheet

8 on the fixing bracket.

– Tightening torque 1.7 Nm (15 lb−in)

4. Connect the mains cable

9 to the screw terminals L1, L2, L3 and PE of the mains

filter:
– Tightening torque 0.5 ... 0.6 Nm (4.4 ... 5.3 lb−in)

5. Connect the supply cable of the regenerative power supply module

::

– Connect the screw terminals L1’, L2’, L3’, PE at the mains filter with the screw

terminals L1, L2, L3, PE at the regenerative power supply module in correct phase
relation.

– Tightening torque 0.5 ... 0.6 Nm (4.4 ... 5.3 lb−in)
– For complying with existing standards (e.g. EN 50178, IEC 61800−3) use shielded

cables from a cable length of 30 cm. Clamp the shield with the clip of the shield
sheet.

6. Connect the supply cable for the controller in the DC−bus connection

; to the screw

terminals +UG, −UG:
– Tightening torque 0.5 ... 0.6 Nm (4.4 ... 5.3 lb−in).

7. Wiring of mains synchronisation:

– Internal mains synchronisation: factory−set bridges

<

– External mains synchronisation: remove bridges

< and connect mains

synchronisation cable

=.

– Tightening torque 0.5 ... 0.6 Nm (4.4 ... 5.3 lb−in).

8. Plug the two covers of the power connections on the regenerative power supply

module.

Advertising