Technical data

General data and operating conditions

3

l

85

EDBMB9340 DE/EN/FR 12.0

(

Stop!

Please strictly observe the following operating conditions, otherwise the
regenerative power supply module may be destroyed.

ƒ

Please observe the permissible mains voltage and current limits (

86). A

higher voltage or current destroy the regenerative power supply module.

ƒ

Regenerative power supply modules must not be connected in parallel in
the DC bus.

ƒ

The use of an additional brake chopper is only permitted if the brake
chopper only limits the DC bus voltage if a power failure or a failure of the
regenerative power supply module occurs; i. e.
– the regenerative power supply module must be designed in a way that the

entire braking energy can be dissipated in every operating state.

– the feedback operation and the brake chopper must not be operated at

the same time.

ƒ

Please observe the circuit proposals (

124) .

ƒ

Please observe national and local regulations!