Commissioning – Lenze E82MVxxx_4Bxxx User Manual
Page 100
Commissioning
Selection of the operating mode
l
100
EDK82MV752 DE/EN/FR 7.1
Recommended operating modes for standard applications
The following table helps you to select the appropriate mode of operation for standard
applications:
Application
Operating mode
Single drives
Setting in C0014
recommended
alternatively
With strongly alternating loads
4
2
With a high starting duty
4
2
With speed control (speed feedback)
2
4
With a high dynamic performance (e.g. positioning and infeed drives)
2
−
With a torque setpoint
5
−
With torque limitation (power control)
2
4
Three−phase reluctance motors
2
−
Three−phase sliding rotor motors
2
−
Three−phase AC motors with a fixedly assigned frequency−voltage
characteristic
2
−
Pump and fan drives with a square−law load characteristic
3
2 or 4
Group drives
(several motors connected to one controller)
Equal motors and equal loads
2
−
Different motors and/or alternating loads
2
−
C0014 = 2: linear V/f characteristic control
C0014 = 3: square−law V/f characteristic control
C0014 = 4: vector control
C0014 = 5: sensorless torque control