Operation with rated power (normal operation), Technical data, Derating of the rated output current – Lenze E82MVxxx_4Bxxx User Manual
Page 78
![background image](/manuals/566195/78/background.png)
Technical data
Operation with rated power (normal operation)
l
78
EDK82MV752 DE/EN/FR 7.1
3.2
Operation with rated power (normal operation)
The data applies to operation with rated mains voltage and a switching frequency of 8 kHz
(sine). For data and restrictions for other switching frequencies: See operating
instructions.
Type
Power
Rated mains voltage
Mains current [A]
Output current [A]
Earth
[kW]
without
with
I
rated
I
max
(60 s)
1)
[kg]
P
rated
Mains choke
E82MV302
3.0
3 PE AC 400 V:
320 V −0 % ... 550 V +0 %
(45 Hz −0 % ... 65 Hz +0 %)
9.5
−
7.3
11.0
9.9
11.7
2)
E82MV402
4.0
12.3
−
9.5
14.2
E82MV552
5.5
16.8
−
13.0
19.5
E82MV752
7.5
21.5
−
16.5
24.8
The output currents apply to operation with fan module E82ZMV or with forced−ventilated Lenze motors/geared motors.
For the operation with self−ventilated Lenze motors/geared motors, the rated output current must be reduced (see
figure)
1)
Currents for periodic load change: 1 min overcurrent time with I
max
and 2 min base load time with 75 % I
rated
2)
Mass incl. fan module E82ZMV
Derating of the rated output current
0,1
10
20
30
40
50
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1
f [Hz]
I/I
N
E82
MV
302
_4B
E8
2M
V4
02
_4
B
E8
2M
V5
52
_4
B
E8
2M
V7
52
_4
B
8200mot339
The current derating data refer to the continuous operation of the
motec
l
without fan module E82ZMV
l
with self−ventilated Lenze motor or Lenze geared motor
l
at a switching frequency of 4 kHz and an ambient temperature of
40 °C or
l
at a switching frequency of 8 kHz and an ambient temperature of
35 °C
I = reduced output current [A]
I
r
= rated output current [A] at a switching frequency of 4 kHz or 8 kHz
f = output frequency