Electrical installation

Relay output connection

5

l

93

EDK82MV752 DE/EN/FR 7.1

5.2

Relay output connection

8200mot410

Function

Relay position

Message
(Lenze setting)

Technical data

X1/K11

NC contact

Open

TRIP

AC 250 V/3 A
DC 24 V/2 A ... DC 240 V/0.22 A

X1/K12

Centre contact

X1/K14

NO contact

Closed

TRIP

PES

HF−shield termination by large surface connection to PE

)

Note!

ƒ

Switching of control signals:
– Use shielded cables
– HF−shield termination by PE connection
– The minimum load for switching the signals through correctly is 12 V and

5 mA. Both values have to be exceeded at the same time.

ƒ

Switching of mains potentials:
– Unshielded cables are sufficient

ƒ

For the protection of the relay contacts a corresponding suppressor circuit is
absolutely required for an inductive or a capacitive load!

ƒ

The service life of the relay depends on the type of load (ohmic, inductive or
capacitive) and the value of the switching capacity.

ƒ

The message that is output can be changed in code C0008 or C0415/1.