Commissioning

Important controller codes

6

l

109

EDK82MV752 DE/EN/FR 7.1

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0003*

v

Saving
parameters
non−volatilely

1

0

Do not save parameters in the EEPROM

Data loss after mains switch−off

1

Always save parameters in the EEPROM

l

Active after every mains
connection

l

Cyclic alteration of parameters via
bus module is not permissible

3

Save your own basic setting in the EEPROM Afterwards save parameter set 1 as

own basic setting with C0002 = 9

C0007

v
uSEr

Fixed
configuration
digital inputs

Change of C0007 is copied into the
corresponding subcode of C0410.
Free configuration in C0410 sets
C0007 = 255!

0

E4

E3

E2

E1

l

CW/CCW = clockwise
rotation/counter−clockwise
rotation

l

DCB = DC injection brake

l

QSP = quickstop

l

PAR = change over parameter set
(PAR1

ó PAR2)

– PAR1 = LOW, PAR2 = HIGH
– The terminal in PAR1 and PAR2

has to be assigned with the
"PAR" function.

– Only use configurations with

"PAR" if C0988 = 0

l

TRIP−Set = external error

0

CW/CCW

DCB

JOG2/3

JOG1/3

1

CW/CCW

PAR

JOG2/3

JOG1/3

2

CW/CCW

QSP

JOG2/3

JOG1/3

3

CW/CCW

PAR

DCB

JOG1/3

4

CW/CCW

QSP

PAR

JOG1/3

5

CW/CCW

DCB

TRIP−Set

JOG1/3

6

CW/CCW

PAR

TRIP−Set

JOG1/3

7

CW/CCW

PAR

DCB

TRIP−Set

8

CW/CCW

QSP

PAR

TRIP−Set

9

CW/CCW

QSP

TRIP−Set

JOG1/3

10

CW/CCW

TRIP−Set

UP

DOWN

C0007

v
uSEr

(Continua
tion)

E4

E3

E2

E1

l

Selection of fixed
setpoints

JOG1/3

JOG2/3

LOW LOW
HIGH LOW
LOW HIGH
HIGH HIGH

Active
C0046
JOG1
JOG2
JOG3

11

CW/CCW

DCB

UP

DOWN

12

CW/CCW

PAR

UP

DOWN

13

CW/CCW

QSP

UP

DOWN

14

CCW/QSP

CW/QSP

DCB

JOG1/3

15

CCW/QSP

CW/QSP

PAR

JOG1/3

16

CCW/QSP

CW/QSP

JOG2/3

JOG1/3

17

CCW/QSP

CW/QSP

PAR

DCB

18

CCW/QSP

CW/QSP

PAR

TRIP−Set

19

CCW/QSP

CW/QSP

DCB

TRIP−Set

C0007

v
uSEr

(Continua
tion)

E4

E3

E2

E1

l

UP/DOWN = motor potentiometer
functions

l

H/Re = manual/remote
change−over

l

PCTRL1−I−OFF = switch off I
component of process controller

l

DFIN1−ON = digital frequency
input 0 ... 10 kHz

l

PCTRL1−OFF = switch off process
controller

20

CCW/QSP

CW/QSP

TRIP−Set

JOG1/3

21

CCW/QSP

CW/QSP

UP

DOWN

22

CCW/QSP

CW/QSP

UP

JOG1/3

23

H/Re

CW/CCW

UP

DOWN

24

H/Re

PAR

UP

DOWN

25

H/Re

DCB

UP

DOWN

26

H/Re

JOG1/3

UP

DOWN

27

H/Re

TRIP−Set

UP

DOWN

28

JOG2/3

JOG1/3

PCTRL1−I−OF

F

DFIN1−ON

29

JOG2/3

DCB

PCTRL1−I−OF

F

DFIN1−ON

30

JOG2/3

QSP

PCTRL1−I−OF

F

DFIN1−ON