Commissioning – Lenze E82MVxxx_4Bxxx User Manual

Page 107

Advertising
background image

Commissioning

Important controller codes

6

l

107

EDK82MV752 DE/EN/FR 7.1

Code

Possible settings

IMPORTANT

No.

Name

Lenze

Selection

C0002*

s
uSEr

Parameter set
management

0

0

Ready

PAR1 ... PAR4:

l

Parameter sets of the controller

l

PAR1 ... PAR4 also contain the
parameters for the function
modules standard I/O, application
I/O, AS interface, system bus (CAN)

FPAR1:

l

Module−specific parameter set of
the fieldbus function modules
INTERBUS, PROFIBUS−DP,
LECOM−B, DeviceNet/CANopen

l

FPAR1 is saved in the function
module

Restoring the
delivery status

1

Lenze setting

ð PAR1

Restore the delivery status in the
parameter set selected

2

Lenze setting

ð PAR2

3

Lenze setting

ð PAR3

4

Lenze setting

ð PAR4

31

Lenze setting

ð FPAR1

Restore the delivery status in the
fieldbus function module

61

Lenze setting

ð PAR1 + FPAR1

Restore the delivery status in the
selected parameter set of the
controller and in the fieldbus function
module

62

Lenze setting

ð PAR2 + FPAR1

63

Lenze setting

ð PAR3 + FPAR1

64

Lenze setting

ð PAR4 + FPAR1

C0002*

s
uSEr

(Continua
tion)

Transferring
parameter sets
with the keypad

By means of the keypad you can
transfer the parameter sets to other
controllers.
During the transmission the access to
the parameters via other channels is
inhibited!

Keypad

ð controller

Overwrite all available parameter sets
(PAR1 ... PAR4, if required FPAR1) with
the corresponding data of the keypad

70

with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet, CANopen

10

with all other function modules