Commissioning

Important controller codes

6

l

110

EDK82MV752 DE/EN/FR 7.1

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0007

v
uSEr

(Continua
tion)

E4

E3

E2

E1

31

DCB

QSP

PCTRL1−I−OF

F

DFIN1−ON

32

TRIP−Set

QSP

PCTRL1−I−OF

F

DFIN1−ON

33

QSP

PAR

PCTRL1−OFF

DFIN1−ON

34

CW/QSP

CCW/QSP

PCTRL1−I−OF

F

DFIN1−ON

35

JOG2/3

JOG1/3

PAR

DFIN1−ON

36

DCB

QSP

PAR

DFIN1−ON

37

JOG1/3

QSP

PAR

DFIN1−ON

38

JOG1/3

PAR

TRIP−Set

DFIN1−ON

39

JOG2/3

JOG1/3

TRIP−Set

DFIN1−ON

40

JOG1/3

QSP

TRIP−Set

DFIN1−ON

C0007

v
uSEr

(Continua
tion)

E4

E3

E2

E1

41

JOG1/3

DCB

TRIP−Set

DFIN1−ON

42

QSP

DCB

TRIP−Set

DFIN1−ON

43

CW/CCW

QSP

TRIP−Set

DFIN1−ON

44

UP

DOWN

PAR

DFIN1−ON

45

CW/CCW

QSP

PAR

DFIN1−ON

46

H/Re

PAR

QSP

JOG1/3

47

CW/QSP

CCW/QSP

H/Re

JOG1/3

48

PCTRL1−OFF

DCB

PCTRL1−I−OF

F

DFIN1−ON

49

PCTRL1−OFF

JOG1/3

QSP

DFIN1−ON

50

PCTRL1−OFF

JOG1/3

PCTRL1−I−OF

F

DFIN1−ON

51

DCB

PAR

PCTRL1−I−OF

F

DFIN1−ON

255

Free configuration in C0410

Read only
Do not change C0007 since settings
in C0410 may get lost

C0010

uSEr

Minimum
output
frequency

0.00

0.00

à

14.5 Hz

{0.02 Hz}

650.00

l

C0010 not effective in the case of
bipolar setpoint selection (−10 V ...
+ 10 V)

l

C0010 only limits the analog input
1

l

In the case of a max. output
frequency > 50 Hz the switching
threshold of the auto DCB in
C0019 has to be increased.

l

From software 3.5: If
C0010 > C0011, the drive does not
start when controller enable is set.

à

Speed setting range 1 : 6 for Lenze
geared motors: For operation with
Lenze geared motors has to be set
necessarily.

C0011

uSEr

Maximum
output
frequency

50.00 7.50

à

87 Hz

{0.02 Hz}

650.00

C0012

uSEr

Acceleration
time main
setpoint

5.00

0.00

{0.02 s}

1300.00 Reference: frequency change 0 Hz ...

C0011

l

Additional setpoint

ðC0220

l

Acceleration times that can be
activated via digital signals

ð

C0101

C0013

uSEr

Deceleration
time main
setpoint

5.00

0.00

{0.02 s}

1300.00 Reference: frequency change C0011...

0 Hz

l

Additional setpoint

ðC0221

l

Deceleration times that can be
activated via digital signals

ð

C0103