Preparation, Mechanical installation – Lenze E82MVxxx_4Bxxx User Manual

Page 83

Advertising
background image

Mechanical installation

Wall mounting

Preparation

4

l

83

EDK82MV752 DE/EN/FR 7.1

4.2.2

Preparation

(

Stop!

The motec can be destroyed by thermal overload!
In case of wall mounting, the fan module E82ZMV has to be mounted in
addition in order to ensure sufficient cooling of the motec.

8200mot402

Æ

5 mm

1

2

3

172

140

180

0

1. Pre−assemble adapter plate:

– Pull the adapter plate into the fixture of the fan module by means of two screws

M5 x 65

– Remove the screws

2. Mount the fan module on the wall with appropriate screws

3. Mark the position of the cable glands on the carrier housing and cut out the

openings

4. Insert the cable glands

5. Place the carrier housing onto the fan module and screw it with 4 screws M5 x 65

mm (scope of supply) onto the fan module

6. Cables which are led into the carrier housing must be stripped. The following applies

to all shielded cables:
– Strip 10 cm of the cable sheath
– Remove the shielding of the cable cores on a length of 8 cm
– 2 cm of the shield are needed for safe shield connection

Advertising