Commissioning

Important controller codes

6

l

112

EDK82MV752 DE/EN/FR 7.1

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0088

Rated motor
current

à

0.0

0.1 (A)

650.0

à

Device−dependent

0.0 ... 2.0 x rated output current of the
controller

C0089

Rated motor
frequency

50

10

{1 Hz}

960

C0090

Rated motor
voltage

à

50

{1 V}

500

à

230 V for 230 V controllers,
400 V for 400 V controllers

C0091

Motor cos

а

0.40

{0.1}

1.0

а

Device−dependent

C0119

v

Configuration of
motor
temperature
monitoring (PTC
input) / earth
fault detection

0

0

PTC input inactive

Earth fault detection
active

l

Configure signal output in C0415

l

If several parameter sets are used,
monitoring has to be set
separately for every parameter set.

l

Deactivate earth fault detection if
the earth fault detection is
actuated unintentionally.

l

If the earth fault detection is
activated, the motor starts with a
delay of approx. 40 ms after
controller enable has been set.

1

PTC input active,
TRIP effected

2

PTC input active,
warning effected

3

PTC input inactive

Earth fault detection
inactive

4

PTC input active,
TRIP effected

5

PTC input active,
warning effected

C0140* Additive

frequency
setpoint
(NSET1−NADD)

0.00

−650.00

{0.02 Hz}

650.00

l

Selection via

j function of the

keypad or parameter channel

l

Acts additively on the main
setpoint

l

Value will be stored when
switching the mains or removing
the keypad

l

C0140 is only transferred during
parameter set transfer with GDC
(not with keypad)

C0148*

s

Identifying
motor data

0

0

Ready

Only when the motor is cold!
1. Inhibit controller, wait until drive

is at standstill

2. Enter the correct values from the

motor nameplate in C0087,
C0088, C0089, C0090, C0091

3. Set C0148 = 1, confirm with

v

4. Enable controller:

The identification
– starts,

c goes out

– the motor "whistles" faintly but

it does not rotate!

– takes approx. 30 s
– is completed when

c is lit

again

5. Inhibit controller

1

Start identification

l

V/f rated frequency (C0015), slip
compensation (C0021) and motor
stator inductance (C0092) are
calculated and saved

l

The motor stator resistance (C0084) =
total resistance of the motor cable and
motor is measured and saved