Vector control, Commissioning – Lenze E82MVxxx_4Bxxx User Manual

Page 103

Advertising
background image

Commissioning

Vector control

6

l

103

EDK82MV752 DE/EN/FR 7.1

6.5

Vector control

The following instructions apply to controllers equipped with a standard−I/O function
module and a three−phase AC motor which has been selected according to a power−based
assignment.

Switch−on sequence

Comment

1.

Connect keypad

2.

Ensure that controller inhibit is active after mains connection

Terminal X3/28 = LOW

3.

Switch on the mains

4.
5.

The keypad is in "Disp" mode after approx. 2 s and indicates the
output frequency (C0050)

The USEr menu is active

6.

Go to the ALL menu

7.

Change to the

f mode to configure the basic settings for your

drive

Blinking on the display: 0050

8.

Adapt the terminal configuration to the wiring (C0007)
Lenze setting: −0−, i. e.
E1: JOG1/3 fixed setpointselection
E2: JOG2/3
E3: DCB DC brake
E4: CW/CCW rotation

9.

Set the minimum output frequency (C0010)
Lenze setting: 0.00 Hz

10.

Set the maximum output frequency (C0011)
Lenze setting: 50.00 Hz

11.

Set the acceleration time T

ir

(C0012)

Lenze setting: 5.00 s

12.

Set the deceleration time T

if

(C0013)

Lenze setting: 5.00 s

13.

Activate the operating mode "vector control" (C0014 = 4)
Lenze setting: Linear V/f characteristic control (C0014 = 2)

14.

Adapt the voltage/current range for the analog setpoint selection
(C0034)
Lenze setting: −0−, (0 ... 5 V/0 ... 10 V/0 ... 20 mA)

Set the DIP switch on the standard I/O to the same
range (see Mounting Instructions for the standard
I/O)

15.

Enter the motor data

See motor nameplate

A

Rated motor speed (C0087)
Lenze setting: 1390 rpm

B

Rated motor current (C0088)
Lenze setting: Depending on the controller

Enter the value for the motor circuit configuration
(star/delta) selected!

C

Rated motor frequency (C0089)
Lenze setting: 50 Hz

D

Rated motor voltage (C0090)
Lenze setting: Depending on the controller

Enter the value for the motor circuit configuration
(star/delta) selected!

E

Motor cos

j (C0091)

Lenze setting: Depending on the controller

Advertising