Technical data
General data and operating conditions
3
l
76
EDK82MV752 DE/EN/FR 7.1
3
Technical data
3.1
General data and operating conditions
Conformity and approval
Conformity
CE
2006/95/EC
Low−Voltage Directive
2004/108/EG
EMC Directive
Approval
UL
UL 508C
Underwriter Laboratories (File No. E132659)
Power Conversion Equipment
CSA
22.2 No. 14
GOST−R
51321.1−2000 No. POCC DE.AN30.Bo8845
51321.3−99
Protection of persons and equipment
Type of protection
IEC/EN60529
NEMA 250 / UL50
IP55 without protective cap on the AIF interface,
protection against accidental contact according to type 12
IEC/EN60529
NEMA 250 / UL50
IP65 with protection cover on the AIF interface,
protection against accidental contact according to type 4
Earth leakage current
IEC/EN 61800−5−1
> 3.5 mA AC
> 10 mA DC
Observe regulations and safety
instructions!
Insulation of control
circuits
IEC/EN 61800−5−1
Safe mains isolation through double (reinforced) insulation
Insulation resistance
IEC/EN 61800−5−1
< 2000 m site altitude: overvoltage category III
> 2000 m site altitude: overvoltage category II
Protective measures
Short circuit, short to earth (protected against short to earth during operation, limited
protection against short to earth on powerup), overvoltage, motor stalling, motor
overtemperature (input for PTC or thermal contact, I
2
t monitoring)
EMC
Complies with requirements according to EN 61800−3
Noise emission
l
cable−guided
IEC/EN 61800−3
Motor mounting:
Compliance with limit class C1
Wall mounting:
– Compliance with the limit class C1 when shielded motor
cables up to a length of 1 m are used
– Compliance with the limit class C2 when shielded motor
cables up to a length of 10 m are used
Noise immunity
Requirements
Standard
Severity
ESD
IEC/EN 61000−4−2
8 kV with air discharge,
4 kV with contact discharge
Cable−guided high
frequency
IEC/EN 61000−4−6
150 kHz ... 80 MHz,
10 V/m 80 % AM (1 kHZ)
Burst
IEC/EN 61000−4−4
3/4, i.e. 2 kV / 5 kHz
Surge (surge voltage
on mains cable)
IEC/EN 61000−4−5
3, i.e. 1.2 / 50
ms,
1 kV phase/phase, 2 kV phase/PE