Technical data

General data and operating conditions

3

l

76

EDK82MV752 DE/EN/FR 7.1

3

Technical data

3.1

General data and operating conditions

Conformity and approval

Conformity

CE

2006/95/EC

Low−Voltage Directive

2004/108/EG

EMC Directive

Approval

UL

UL 508C

Underwriter Laboratories (File No. E132659)
Power Conversion Equipment

CSA

22.2 No. 14

GOST−R

51321.1−2000 No. POCC DE.AN30.Bo8845
51321.3−99

Protection of persons and equipment

Type of protection

IEC/EN60529
NEMA 250 / UL50

IP55 without protective cap on the AIF interface,
protection against accidental contact according to type 12

IEC/EN60529
NEMA 250 / UL50

IP65 with protection cover on the AIF interface,
protection against accidental contact according to type 4

Earth leakage current

IEC/EN 61800−5−1

> 3.5 mA AC
> 10 mA DC

Observe regulations and safety
instructions!

Insulation of control
circuits

IEC/EN 61800−5−1

Safe mains isolation through double (reinforced) insulation

Insulation resistance

IEC/EN 61800−5−1

< 2000 m site altitude: overvoltage category III

> 2000 m site altitude: overvoltage category II

Protective measures

Short circuit, short to earth (protected against short to earth during operation, limited
protection against short to earth on powerup), overvoltage, motor stalling, motor
overtemperature (input for PTC or thermal contact, I

2

t monitoring)

EMC

Complies with requirements according to EN 61800−3

Noise emission

l

cable−guided

IEC/EN 61800−3

Motor mounting:
Compliance with limit class C1

Wall mounting:

– Compliance with the limit class C1 when shielded motor

cables up to a length of 1 m are used

– Compliance with the limit class C2 when shielded motor

cables up to a length of 10 m are used

Noise immunity

Requirements

Standard

Severity

ESD

IEC/EN 61000−4−2

8 kV with air discharge,
4 kV with contact discharge

Cable−guided high
frequency

IEC/EN 61000−4−6

150 kHz ... 80 MHz,
10 V/m 80 % AM (1 kHZ)

Burst

IEC/EN 61000−4−4

3/4, i.e. 2 kV / 5 kHz

Surge (surge voltage
on mains cable)

IEC/EN 61000−4−5

3, i.e. 1.2 / 50

ms,

1 kV phase/phase, 2 kV phase/PE