MAINTENANCE/SERVICE

Form 169009

76

Model Year - 2009

C

8.8 HYDRAULICS

The CA20 Combine Adapter’s hydraulic system
provides oil for the header draper and knife
drives as well as the adapter feed draper. Reel
hydraulics are provided by the combine.

8.8.1 RESERVOIR

The adapter frame is used as a reservoir.
Refer to Section 8.4, Recommended Fluids and
Lubricants for proper oil.

8.8.1.1 Oil

Level

Check oil level every 25 hours at sights (A) and
(B) with cutterbar just touching ground. Check
when oil is cold and with center link retracted.

Nominal – Normal Terrain: Maintain level so
lower sight (A) is full and upper sight (B) is
empty.

Maximum – Hilly Terrain: Maintain level so
sight (A) is full and sight (B) is up to 1/2 filled.

Minimum – Level Ground: For slopes of 6° or
less, oil level may be kept slightly lower if
desired. Maintain level so sight (A) is ½ filled or
higher.

NOTE

When ambient temperatures are above
35° C (95° F), to prevent overflow at
breather under operating temperatures, it
may be necessary to lower oil level
slightly.

8.8.1.2 Adding Hydraulic Oil

CAUTION

Stop engine and remove key from ignition
before leaving operator's seat for any
reason. A child or even a pet could engage
an idling machine.

a. Turn filler cap (C) counterclockwise until loose

and remove cap.

b. Add warm (room temperature) SAE 15W-40 oil

to required level. Refer to Section 8.4,
Recommended Fluids and Lubricants for proper
oil.

IMPORTANT

Warm (room temperature) oil will flow
through the screen better than cold oil.
DO NOT REMOVE THE SCREEN.

c. Reinstall filler cap. Hand tighten.

A

B

B

A