Programming and Parameters

5-5

PowerFlex 700L Frames 2, 3A, and 3B Liquid-Cooled AC Drives User Manual

Publication 20L-UM001E-EN-P

Affected 700S Phase II
Control Parameters

When a PowerFlex 700L Liquid-Cooled drive is present, the following
700S Phase II Control functions are affected:

• Supports DPI communication ports 1 through 6.

• Supports DPI Type III communication with an active converter.

• Supports the power structure fault latch and multiple NTCs.

• Supports IT (Junction Temperature Calculation) mode.

• Bus regulator mode is disabled when an active converter is present.

• Fast Flux-up current is limited to 40% of motor nameplate current

instead of 70% (PowerFlex 700S).

Utility File

In the Utility file - Diagnostics group, the following parameters are
available when a PowerFlex 700L Liquid-Cooled AC drive is present.

No.

Name
Description

Values

332

700L EventStatus

Indicates the presence of certain drive anomalies for the PowerFlex 700L Liquid-Cooled drive.
Bit 0 [Dsat Phs U1] indicates that the primary structure detected a Dsat on phase U.
Bit 1 [Dsat Phs V1] indicates that the primary structure detected a Dsat on phase V.
Bit 2 [Dsat Phs W] indicates that the primary structure detected a Dsat on phase W.
Bit 3 [Ovr Current1] indicates that the primary structure detected an over current.
Bit 4 [Ovr Volt1] indicates that the primary structure detected an over voltage.
Bit 5 [Asym DcLink1] indicates that the primary structure detected an unbalanced DC Link.
Bit 6 [Pwr Suply1]indicates that the primary structure detected a power supply failure.
Bit 7 [HW Disable1] indicates that the primary structure detected a hardware disable.
Bit 8 [Latch Err1] indicates that the primary structure fault was generated but no indicating bit was set.
Bit 9 [Fan Fail1] indicates
Bit 12 [NonCnfgAlarm] indicates
Bit 13 [Cnv Faulted] indicates
Bit 14 [Cnv NotLogin] indicates the converter was expected but none logged in.
Bit 15 [Cnv NotStart] indicates the converter was commanded to start but did not become active.
Bit 16 [Dsat Phs U2] indicates the second structure detected a Dsat on phase U.
Bit 17 [Dsat Phs V2] indicates the second structure detected a Dsat on phase V.
Bit 18 [Dsat Phs W2] indicates the second structure detected a Dsat on phase W.
Bit 19 [Ovr Current2] indicates the second structure detected an over current.
Bit 20 [Ovr Volt2] indicates the second structure detected an over voltage.
Bit 21 [Asym DcLink2] indicates the second structure detected an unbalanced DC Link.
Bit 22 [Pwr Suply2] indicates the second structure detected a power supply failure.
Bit 23 [HW Disable2] indicates the second structure detected a hardware disable.
Bit 24 [Latch Err2] indicates the second structure fault was generated but no indicating bit was set.
Bit 25 [Fan Fail2] indicates
Note: This parameter was added for firmware version 2.03.

Bit
Definition

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Fa

n F

ai

l2

Lat

ch Er

r2

HW

Disa

bl

e2

Pwr Sup

ly

2

A

sy

m

D

cLi

nk

2

Ovr V

olt2

Ovr Cur

rent

2

Dsat P

hs

W2

Dsat P

hs

V2

Dsat P

hs

U2

Cn

v NotStar

t

Cn

v Not

Login

Cn

v F

aulted

NonCnf

gAlar

m

Reser

ved

Reser

ved

Fa

n F

ai

l1

Lat

ch Er

r1

HW

Disa

bl

e1

Pwr Sup

ly

1

A

sy

m

D

cLi

nk

1

Ovr V

olt1

Ovr Cur

rent

1

Dsat P

hs

W1

Dsat P

hs

V1

Dsat P

hs

U1

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True

Advertising