Catalog number explanation – Rockwell Automation 20L PowerFlex 700L Liquid-Cooled Adjustable Frequency AC Drive User Manual

Page 13

Advertising
background image

Overview

P-5

PowerFlex 700L Frames 2, 3A, and 3B Liquid-Cooled AC Drives User Manual

Publication 20L-UM001E-EN-P

Catalog Number Explanation

a

Drive

Code

Type

20L

PowerFlex 700L

b

Voltage Rating

Code

Voltage

Ph.

C

400V AC

3

D

480V AC

3

E

600V AC

3

F

690V AC

3

c1

ND Rating

400V, 60 Hz Input

Code

Amps

Hp (KW)

Frame

360

360

268 (200)

2

650

650

500 (370)

3A

1K2

1250

960 (715)

3B

c2

ND Rating

480V, 60 Hz Input

Code

Amps

Hp (KW)

Frame

360

360

300 (224)

2

650

650

600 (445)

3A

1K2

1250

1150 (860)

3B

c3

ND Rating

600V, 60 Hz Input

Code

Amps

Hp (KW)

Frame

425

425

465 (345)

3A

800

800

870 (650)

3B

1K1

1175

1275 (950)

3B

Must operate at 2 kHZ PWM only, and only as a
stand-alone inverter module (“K” in position 13).

c4

ND Rating

690V, 60 Hz Input

Code

Amps

Hp (KW)

Frame

380

380

475 (355)

3A

705

705

881 (657)

3B

1K0

1050

1310 (980)

3B

Must operate at 2 kHZ PWM only, and only as a
stand-alone inverter module (“K” in position 13).

Position

1-3

4

5-7

8

9

10

11

12

13

14

15

16

17

18

20L

E

800

A

0

E

N

N

A

N

1

0

W

A

a

b

c

d

e

f

g

h

i

j

k

l

m

n

d

Enclosure

Code

Type

Conformal

Coating

A

NEMA/UL Type 1, IP20

No

N

Open-Chassis Style/IP00

No

Frame 3 complete drive.

Frame 2 drive and Frame 3 input filter and power
modules.

e

HIM

Code

Operator Interface

0

No HIM/Blank Cover

3

Full Numeric LCD

C

Door-Mounted Full Numeric LCD

Frame 2 and Frame 3 power modules.

Frame 3 complete drive only.

f

Documentation

Code

Documents

Ship Carton

E

English Doc Set

Yes

N

No Documentation

Yes

Q

No Documentation

No

g

Brake

Code

w/Brake IGBT

N

No

h

Brake Resistor

Code

w/Resistor

N

No

i

Equipment Type

Code

Description

Frame

A

Complete Regenerative

Drive - Std. Interrupt Rating

2, 3A, and 3B

C

Input Filter

3A and 3B

E

Combined Active Converter/

Inverter Power Module

3A only

G

Active Converter

Power Module

3B only

J

Inverter Power Module -

Coupled Version

3B only

K

Inverter Power Module -

Common DC Bus Version

3B only

L

Dual Inverter Power Module

3A only

P

Active Converter Power

Module - Stand Alone Version

3B only

X

Spare Power Module

3A and 3B

No control cassettes.

j

Comm Slot

Code

Communication Option

DPI

User-Installed
Kit Cat. No.

N

None

N

C

ControlNet (Coax) - DPI

20-COMM-C

D

DeviceNet - DPI

20-COMM-D

E

EtherNet/IP - DPI

20-COMM-E

1

DriveLogix Comm Option,

ControlNet (Coax)

2

DriveLogix Comm Option,

ControlNet Redundant (Coax)

3

DriveLogix Comm Option,

ControlNet (Fiber)

4

DriveLogix Comm Option,

ControlNet Redundant (Fiber)

5

DriveLogix Comm Option,

DeviceNet (Open

Connection)

6

DriveLogix Comm Option,

DeviceNet (Twisted Pair)

For 700S Phase II Control with DriveLogix5730,
comm. slot option selections are mutually
exclusive. For two communication adapters, (DPI
and DriveLogix), select the DriveLogix comm.
slot option and order the DPI user installed kit
catalog number separately.

700 Vector Control uses DPI comm. slot options
only.

DriveLogix comm. slot options require 700S
Phase II Control with DriveLogix5730.

Advertising