Rockwell Automation 20L PowerFlex 700L Liquid-Cooled Adjustable Frequency AC Drive User Manual

Page 124

Advertising
background image

A-8

Supplemental Drive Information

PowerFlex 700L Frames 2, 3A, and 3B Liquid-Cooled AC Drives User Manual
Publication 20L-UM001E-EN-P

Table A.I 650 Volt DC Input Fusing

Table A.J 810 Volt DC Input Fusing

Table A.K 932 Volt DC Input Fusing

Drive
Catalog
Number

Fram

e

HP (kW) Rating

DC Input
Rating

Bussmann Fuse

ND

HD

Amps

Amps

Catalog No.

20LD650

3A

600 (445)

440 (325)

1250

(1)

(1)

Only the Dual Inverter for PowerFlex 700L Frame 3A is available as a DC input inverter.

2000

170M6621

(2)

(2)

Two 1000A Bussmann 170M6614 fuses per phase can also be used.

20LD1K2

3B

1150 (860)

845 (630)

1250

2000

170M6621

(2)

Drive
Catalog
Number

Fra

m

e

HP (kW) Rating

DC Input
Rating

Bussmann Fuse

ND

HD

Amps

Amps

Catalog No.

20LE425

3A

465 (345)

345 (255)

850

(1)

(1)

Only the Dual Inverter for PowerFlex 700L Frame 3A is available as a DC input inverter.

1400

170M6701

(2)

(2)

Two 700A Bussmann 170M6695 fuses per phase can also be used.

20LE800

3B

870 (650)

640 (480)

800

1250

170M6700

(3)

(3)

Two 630A Bussmann 170M6694 fuses per phase can also be used.

20LE1K1

3B

1275 (955)

935 (695)

1175

900 (2 per phase) 170M6697

Drive
Catalog
Number

Frame

HP (kW) Rating

DC Input
Rating

Bussmann Fuse

ND

HD

Amps

Amps

Catalog No.

20LF380

3A

475 (355)

350 (260)

760

(1)

(1)

Only the Dual Inverter for PowerFlex 700L Frame 3A is available as a DC input inverter.

1250

170M6700

(2)

(2)

Two 630A Bussmann 170M6694 fuses per phase can also be used.

20LF705

3B

881 (657)

650 (485)

705

1100

170M6699

(3)

(3)

Two 550A Bussmann 170M6693 fuses per phase can also be used.

20LF1K0

3B

1315 (980)

965 (720)

1050

800 (2 per phase) 170M6696

Advertising