3-14

Frame 3A and 3B Installation

PowerFlex 700L Frames 2, 3A, and 3B Liquid-Cooled AC Drives User Manual
Publication 20L-UM001E-EN-P

Figure 3.14 Removing the Frame 3B Active Converter Control Cassette

Removing the Inverter
Power Module Control
Cassette

For Frame 3A drives (with a combined Active Converter/Inverter Power
Module) or Frame 3B drives (with a separate Inverter Power Module), the
Inverter is equipped with either the standard PowerFlex 700 Vector Control
cassette or an optional PowerFlex 700S Phase II Control cassette. In either
case, the cassette is removed in the same way.

PowerFlex 700 Vector Control Cassette (standard)

Figure 3.15

shows the location and removal of the Inverter Power Module’s

standard PowerFlex 700 Vector Control cassette to access its terminal
blocks for control wiring. See the PowerFlex 700 Adjustable Frequency AC
Drive User Manual - Series B, publication 20B-UM002, for control wiring
details.

Internal DPI Cable

40-Pin

Ribbon Cable

Synchronization Cable

(For use with coupled Inverter Power

Modules with 700 Vector Control only)

Synchronization Cable

(For use with coupled Inverter Power

Modules with 700S Phase II Control only)

P2

Pin 1

Detail

P1