Rockwell Automation 20L PowerFlex 700L Liquid-Cooled Adjustable Frequency AC Drive User Manual

Page 54

Advertising
background image

3-6

Frame 3A and 3B Installation

PowerFlex 700L Frames 2, 3A, and 3B Liquid-Cooled AC Drives User Manual
Publication 20L-UM001E-EN-P

Figure 3.5 Frame 3A Dual Inverter Power Module Installation Dimensions

44 (1.75)

23 (0.90)

DETAIL A

Ш14 (Ш0.56)

21 (0.81)

25 (1.00)

51 (2.00)

368 (14.50)

55 (2.16)

57 (2.24)

57 (2.24)

37 (1.46)

100 (3.95)

100 (3.95)

86 (3.39)

86 (3.39)

72 (2.83)

72 (2.83)

24 (0.94)

255 (10.05)

Top

Bot

119 (4.67)

119 (4.67)

119 (4.67)

119 (4.67)

119 (4.67)

396 (15.59)

1326 (52.20)

265 (10.44)

402 (15.82)

567 (22.32)

51 (1.99)

DC Pos.

DC

Neg.

See

DETAIL A

See

DETAIL B

97 (3.82)

44 (1.75)

21 (0.81)

38 (1.50)

19 (0.73)

38 (1.50)

DETAIL B

DETAIL C

Ш14 (Ш0.56)

Dimensions are in millimeters and (inches).

Ш14 (Ш0.56)

44 (1.75)

44 (1.75)

16 (0.63)

76 (2.98)

16 (0.63)

BACK VIEW

LEFT SIDE VIEW

FRONT VIEW

AIRFLOW

U/T1

V/T2

W/T3

U/T1

V/T2

W/T3

15 (0.60)

700 (27.58)

362 (14.25)

12 (0.45)

39 (1.56)

175 (6.89)

GRD

51 (1.99)

1200

(47.25)

39 (1.56)

175 (6.89)

See DETAIL C

Approximate Weight

Power Module

Power Module and Packaging

113.9 kg (251 lb)

145.6 kg (321 lb)