Protection and diagnostics (cont.), Figure 1.9 – overload trip curves, Figure 1.10 – restart trip curves after auto reset – Rockwell Automation 1560E SMC Flex Smart Motor Controller User Manual

Page 20: 10 product overview

Advertising
background image

1-10

Product Overview

% 5-" %. 0

Approximate trip time for 3-phase balanced
condition from cold start.

Approximate trip time for 3-phase balanced
condition from hot start.

Class 10

Class 15

Class 20

Class 30

Multiples of FLC

Multiples of FLC

Multiples of FLC

Multiples of FLC

Ap

p

ro

xi

m

at

e

T

ri

p

T

im

e

(se

co

n

d

s)

Ap

p

ro

xi

m

at

e

T

ri

p

T

im

e

(se

co

n

d

s)

A

p

pr

ox

im

at

e

T

ri

p

T

im

e

(s

ec

o

nds

)

Ap

p

ro

xi

m

at

e

T

ri

p

T

im

e

(se

co

n

d

s)

1.0

10.0

100.0

1000.0

10000.0

1

10

2

3

9

8

7

6

5

4

0.1

1.0

10.0

100.0

1000.0

1

10

2

3

9

8

7

6

5

4

1.0

10.0

100.0

1000.0

10000.0

1

10

2

3

9

8

7

6

5

4

1.0

10.0

100.0

1000.0

10000.0

1

10

2

3

9

8

7

6

5

4

Approximate trip time for 3-phase balanced
condition from cold start.

Approximate trip time for 3-phase balanced
condition from hot start.

Class 10

Class 15

Class 20

Class 30

Multiples of FLC

Multiples of FLC

Multiples of FLC

Multiples of FLC

Ap

p

ro

xi

m

at

e

T

ri

p

T

im

e

(se

co

n

d

s)

Ap

p

ro

xi

m

at

e

T

ri

p

T

im

e

(se

co

n

d

s)

A

p

pr

ox

im

at

e

T

ri

p

T

im

e

(s

ec

o

nds

)

Ap

p

ro

xi

m

at

e

T

ri

p

T

im

e

(se

co

n

d

s)

1.0

10.0

100.0

1000.0

10000.0

1

10

2

3

9

8

7

6

5

4

0.1

1.0

10.0

100.0

1000.0

1

10

2

3

9

8

7

6

5

4

1.0

10.0

100.0

1000.0

10000.0

1

10

2

3

9

8

7

6

5

4

1.0

10.0

100.0

1000.0

10000.0

1

10

2

3

9

8

7

6

5

4

Approximate trip time for 3-phase balanced
condition from cold start.

Approximate trip time for 3-phase balanced
condition from hot start.

Class 10

Class 15

Class 20

Class 30

Multiples of FLC

Multiples of FLC

Multiples of FLC

Multiples of FLC

Ap

p

ro

xi

m

at

e

T

ri

p

T

im

e

(se

co

n

d

s)

Ap

p

ro

xi

m

at

e

T

ri

p

T

im

e

(se

co

n

d

s)

A

p

pr

ox

im

at

e

T

ri

p

T

im

e

(s

ec

o

nds

)

Ap

p

ro

xi

m

at

e

T

ri

p

T

im

e

(se

co

n

d

s)

1.0

10.0

100.0

1000.0

10000.0

1

10

2

3

9

8

7

6

5

4

0.1

1.0

10.0

100.0

1000.0

1

10

2

3

9

8

7

6

5

4

1.0

10.0

100.0

1000.0

10000.0

1

10

2

3

9

8

7

6

5

4

1.0

10.0

100.0

1000.0

10000.0

1

10

2

3

9

8

7

6

5

4

Figure 1.9 – Overload Trip Curves

100000

1000

100

10

1

0

100%

1000%

Percent Full Load Current Setting

Auto Reset Times:
Class 10 =

90 s

Class 15 = 135 s
Class 20 = 180 s
Class 30 = 270 s

Class 10
Class 15
Class 20
Class 30

Se

co

nd

a

100000

1000

100

10

1

0

100%

1000%

Percent Full Load Current Setting

Auto Reset Times:
Class 10 =

90 s

Class 15 = 135 s
Class 20 = 180 s
Class 30 = 270 s

Class 10
Class 15
Class 20
Class 30

Class 10
Class 15
Class 20
Class 30

Se

co

nd

a

Figure 1.10 – Restart Trip Curves after Auto Reset

Protection and Diagnostics
(cont.)

Advertising