Calculating Program Timing

Chapter 9

9-8

Bit and Word Instructions for PLCĆ5/10, Ć5/12, Ć5/15, and Ć5/25

Processors

Table 9.N shows timing and memory requirements for bit and word
instructions for PLC-5/10, -5/12, -5/15, and -5/25 processors.

Table 9.N

Timing and Memory Requirements for Bit and Word Instructions

for PLCĆ5/10, Ć5/12, Ć5/15, and Ć5/25 Processors

Category

Code

Title

Execution Time (

µ

s)

Integer

True

False

Execution Time (

µ

s)

Floating Point

True

False

Words of

Memory

2

Relay

XIC

examine if closed

1.3

0.8

1

1

XIO

examine if open

OTL

output latch

1.6

OTU

output unlatch

OTE

output energize

1.6

1.6

Branch

branch end

0.8

0.8

1

next branch

branch start

Timer and Counter

TON

timer on (0.01 base)

(1.0 base)

39
44

27
28

2Ć3

TOF

timer off (0.01 base)

(1.0 base)

30
30

43
51

RTO

retentive timer on

(0.01 base)

(1.0 base)

39
44

24
24

CTU

count up

32

34

CTD

count down

34

RES

reset

30

14

1

For every bit address above the first 256 words of memory in the data table, add 0.8

µ

s to the execution time and 1 wordd of memory to the requirements.

2

Use the smaller number if all addresses are below word 4096; use the larger number if all addresses are above 4096.