Chassis configuration plug for power supply – Rockwell Automation 1785-LTx,D17856.2.1 Classic PLC-5 Programmable Controllers Users Manual User Manual

Page 141

Advertising
background image

Selecting Switch Settings

Appendix A

A-3

Position the configuration plug for the power supply you add to
your chassis.

USING

POWER SUPPLY

MODULE IN

THE CHASSIS?

1.

Locate the chassis configuration plug (between

the first two left most slots of the chassis).

2.

Set the I/O chassis configuration plug.

The default setting is N (not using a power

supply module in the chassis).

N

Y

N

Y

N

Y

Set Y when you install

a power supply module

in the chassis.

Set N when you

use an external

power supply.

IMPORTANT: You cannot power a single I/O chassis

with both a power supply module and an external

power supply.

17075

Chassis Configuration Plug

for Power Supply

Advertising