28 Planning Your Configuration and Data Mapping Your Devices

Mapping RediSTATION Output Data for an M0 File Data Table
Write

The RediSTATION operator interface’s output is mapped to the
1747-SDN module’s M0 file. Within the output byte is a bit for the
indicator light. The output data file is then transferred from the SLC
500 processor application to turn the light on or off.

RediSTATION Output Byte

1

2

The SLC 500 processor’s output
data file containing the indicator
light bit for the RediSTATION
operator interface is transferred
to the 1747-SDN Module’s M0
file data table.

What’s Happening?

The M0 file data table is then
sent to the RediSTATION
operator interface via a polled
message from which the
RediSTATION operator interface
receives its indicator light bit.

N8:0

0000 0000 0000 000L

N8:1

0000 0000 0000 0000

N8:2

0000 0000 0000 0000

N8:3

0000 0000 0000 0000

N8:4

0000 0000 0000 0000

PLC-5 Processor

Output Data File

1

N8:149

0000 0000 0000 0000

2

1747-SDN Module M1 File Data Table

Start/Stop Station Node Address 7

L = Fit for the Station
Indicator Light

= Unused Bits

1 byte

L

Word 0

Word 1

Word 2

Word 3

Word 4

Up to
Word 149

L

1

Example: The RediSTATION operator interface’s indicator light (L)
is taken from N8:1/0 in the SLC 500 processor’s output data file.

1

This mapping is based upon the example in chapter 4.

The actual mapping for your system may be different.