Publication 1734-UM008B-EN-P - August 2005

A-30 1734-POINT I/O Module/RSLogix5000 Controller Tag Reference

To enter values from +128 to +255, use these conversion formulas:

Decimal Position Note:

Desired Decimal Position Value - 256 = Entered Decimal
Position Value.
Example: For a divisor of 200, 200 - 256 = -56

Gate Interval Note:

Desired Gate Interval Value - 256 = Entered Gate Interval Value.
Example: For a Gate Interval of 200, 200 - 256 = -56

Scalar Note:

Desired Scalar Value - 256 = Entered Scalar Value.
Example: For a Scalar of 128, 128 - 256 = -128

1734-IJ
1 Channel 5V DC Encoder / Counter
1734-IK
1 Channel 15-24V DC Encoder / Counter

Configuration Data

Data Type

Default
Value

Valid Data Values

SS Counter Control

SS Counter Reset

SS Counter Preset

SS Value Reset

SINT
BIT 0

BIT 1

BIT 2

0

0=Count Unchanged
1=Count Cleared
0=Count Unchanged
1=Count Set to Preset
0=Count Unchanged
1=Count Cleared