Rockwell Automation 1734-ACNR POINT I/O ControlNet Adapter User Manual User Manual

Page 97

Advertising
background image

Publication 1734-UM008B-EN-P - August 2005

1734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-35

SSI Word Delay Time Note:

To enter Delay values from +32,768 to +65,535

µs, use this conversion

formula:

Desired Delay Value (in

µs) - 65536 = Entered Delay Value (in

µs).
Example: For a 40ms delay time, 40000 - 65536 = -25536

Sensor Resolution Note:

To enter Resolution values from +32,768 to +65,535

µs, use this

conversion formula:

Desired Resolution Value - 65536 = Entered Resolution Value.
Example: For a 40,000 count sensor, 40000 - 65536 = -25536

Sensor Cycle Note:

To enter Cycle values from +32,768 to +65,535, use this conversion
formula:

Desired Cycle Value - 65536 = Entered Cycle Value.
Example: For 50,000 sensor cycle rotations, 50000 - 65536 =
-15536

1734-SSI
1 Channel Synchronous Serial Interface

Configuration Data

Data Type

Default
Value

Valid Data Values

Compare 1 Control;

Compare1_0
Compare1_1

SINT
BIT 0
BIT 1

0

00=Off
01=Up Direction
10=Down Direction
11=Both Directions

Advertising