Install and Replace Components Chapter 6

PanelView Plus 400 and 600 Terminals

Follow these steps to install a communication module.

1. Disconnect power from the terminal.

2. Set the terminal, display side down, on a clean, flat, stable

surface.

3. Remove the label covering the connectors on the base unit of

the terminal.

4. Position the communication module over back of the terminal

so that the connector on bottom of communication module align
with the connector on the base unit.

REMOVE LABEL TO INSTALL
COMMUNICATION MODULE

Captive
Screws

Tighten this

screw first.