Insert the new battery, Push down on the logic module until firmly seated, Replace the bezel – Rockwell Automation 2711P PanelView Plus Terminal User Manual User Manual

Page 155: Remove the display module bezel, Disconnect power from the terminal

Advertising
background image

Publication 2711P-UM001J-EN-P - November 2009

155

Install and Replace Components Chapter 6

8. Insert the new battery.

9. Attach the logic module by aligning the two connectors on the

bottom of the module with the connectors on the terminal.

10. Push down on the logic module until firmly seated.

11. Tighten the six captive screws that secure the logic module to a

torque of 0.58 Nm (5…7 lb•in).

12. Attach the communication module (if necessary) and tighten the

four screws to a torque of 0.58 Nm (5…7 lb•in).

Replace the Bezel

It is not necessary to remove the logic module or communication
module before removing the bezel, except on the PanelView Plus 700
terminal.

Remove the Display Module Bezel

Follow these steps to remove the display module bezel on a 700 to
1500 terminal.

1. Disconnect power from the terminal.

2. Set the terminal, display side down, on a flat stable surface.

IMPORTANT

Use only replacement battery 2711P-RY2032.

ATTENTION

Wear a properly grounded ESD wristband before
touching any of the electronic components in the
logic module.

Advertising