7 reinstalling the cover on the vsm500 unit – Rockwell Automation VSM500 Integrated Drive/Motor DeviceNet Option Board User Manual

Page 19

Advertising
background image

Installing the DeviceNet Option Board

2-5

2.6

Connecting the DeviceNet Option Board and VSM500
Unit to the Network

Step 1. Verify that power has been removed from the VSM500 unit and network.

Step 2. Connect a DeviceNet cable to the network.

Important: Maximum cable length depends on data rate. Refer to the DeviceNet

Cable System Planning and Installation Manual.

Step 3. Connect a Linear plug to the DeviceNet cable.

Step 4. Connect the DeviceNet cable to the VSM500 unit. Figure 2.5 shows an

example.

2.7

Reinstalling the Cover on the VSM500 Unit

Step 1. Connect the display cable and install the cover (see figure 2.5).

Step 2. Tighten the screws on the cover to 1.46 Nm (13 in-lb).

Figure 2.4 – Connecting a 10-Pin Linear Plug to the Cable

Table 2.4 – Linear Plug Terminal Connections

Terminal

Color

Signal

Function

5

Red

VDC+

Power Supply

4

White

CAN_H

Signal High

3

Bare

SHIELD

Shield

2

Blue

CAN_L

Signal Low

1

Black

COMM

Common

5
4
3
2
1

Red

White

Bare

Blue
Black

!

ATTENTION: The cover screws must be securely tightened in order to
properly ground the cover. Verify that all four cover screws are tightened
to 1.46 Nm (13 in-lb) before applying power to the VSM500 unit. Failure
to obsere this precaution could result in severe bodily injury or loss of life.