Configuring the VSM500 Unit and DeviceNet Option Board
3-11
Step 2. Select the bits (an “X” appears) that you want reviewed for changes, and then
click Save to Device.
Step 3. Click OK to close the dialog box.
3.13 Resetting the Devicenet Option Board
For changes to some parameters in the option board to take effect, you must reset the
option board. Parameter 113 [
RESET
] can be used to reset the option board, restore
the option board parameters to their factory default settings, or restore the drive
parameters to their factory default settings. To reset the option:
Step 1. In the Device Configuration - Enhanced Mode dialog box (see figure 3.8),
double-click parameter 113 [
RESET
]. The Device Configuration - Modify
Enumerated Parameter dialog box appears.
Figure 3.16 – Modifying the Change of State Mask
!
ATTENTION: Resetting the option may fault the VSM500 unit, resulting
in equipment damage, injury, or death. Ensure that the VSM500 unit can
stop safely before resetting it. Failure to observe this precaution could
result in severe bodily injury or loss of life.
Figure 3.17 – Modifying the Reset Parameter