5.2

Example of I/O Messaging

For example, Output Assembly 21 uses the following data format:

:

Input Assembly 71 uses the following data format:

Figure 5.1 illustrates how data in Output Assembly 21 and Input Assembly 71 will be
transmitted between a VSM500 unit and an SLC processor. Notice that the terms
input and output are defined from the scanner’s point of view. Also notice that explicit
messaging can be transmitted as well.

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

NetRef

Net

Control

Fault
Reset

RunRev

RunFwd

1

Not Used

2

Speed Reference RPM (Low Byte)

3

Speed Reference RPM (High Byte)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

At
Reference

RefFrom
Net

CtrlFrom
Net

Ready

Running
Reverse

Running
Forward

Faulted

1

Not Used

2

Speed Actual RPM (Low Byte)

3

Speed Actual RPM (High Byte)

Figure 5.1 – Example I/O Image

SLC

Scanner

VSM500 Unit and DeviceNet Option

Devic

eN

et

Output
Image
(Write)

Input
Image
(Read)

Explicit

Message

Handler

Explicit

Message

Buffer

0 - Network Status
1 - Not Used
2 - Actual Speed (Low Byte)
3 - Actual Speed (High Byte)

0 - Network Control
1 - Not Used
2 - Speed Reference (Low Byte)
3 - Speed Reference (High Byte)