C.7 class code 0x0f – parameter object – Rockwell Automation VSM500 Integrated Drive/Motor DeviceNet Option Board User Manual

Page 82

Advertising
background image

C-14

VSM500 DeviceNet Option Board

C.7 Class Code 0x0F – Parameter Object

Class Attributes

Instance 1 through 113 Attributes

Attribute ID

Access Rule

Name

Data Type

Value

1

Get

Revision

UINT

1

2

Get

Max Instance

UINT

113

8

Get

Parameter Class Descriptor

WORD

0x0B

9

Get

Configuration Assembly
Instance

UINT

0

10

Get

Native Language

USINT

0 = English

Attribute

ID

Access

Rule

Name

Data Type

Value

1

Get/Set

Parameter Value

(1)

(2)

2

Get

Link Path Size

USINT

7

3

Get

Link Path

0x20, 0x0F, 0x25, XX, XX,

0x30, 0x01

3

4

Get

Descriptor

WORD

Bit 1

Bit 2
Bit 4
Bit 5
Bit 6

Supports enum
strings
Supports scaling
Read only
Monitor
Extended precision
scaling

5

Get

Data Type

USINT

1 = 16 bit word
2 = 16 bit unsigned integer
3 = 16 bit signed integer

6

Get

Data Size

USINT

2

7

Get

Parameter Name
String

SHORT_STRING

(2)

8

Get

Units String

SHORT_STRING

(2)

9

Get

Help String

SHORT_STRING

0

10

Get

Minimum Value

data type

(2)

11

Get

Maximum Value

data type

(2)

12

Get

Default Value

data type

(2)

13

Get

Scaling Multiplier

UINT

1

14

Get

Scaling Divisor

UINT

1

15

Get

Scaling Base

UINT

1

16

Get

Scaling Offset

INT

0

17

Get

Multiplier Link

UINT

0

18

Get

Divisor Link

UINT

0

19

Get

Base

Link

UINT 0

20

Get

Offset Link

UINT

0

21

Get

Decimal Precision

USINT

(2)

1

Specified in descriptor, data type, and data size.

2

Value varies based on parameter instance.

3

Refer to the DeviceNet specification for a description of the connection path.