Rockwell Automation VSM500 Integrated Drive/Motor DeviceNet Option Board User Manual

Page 75

Advertising
background image

DeviceNet Objects

C-7

Instance Data Format: Output Assemblies

1

If speed references are outside of their min/max limits, the drive ignores them and previous speed

reference will be maintained.

2

0 = 0 Hz, 1200 = 120.0 Hz.

Instance 1 Data Format (Basic Contactor Output Assembly)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Run

Instance 2 Data Format (Basic Overload Output Assembly)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Fault Reset

Instance 3 Data Format (Basic Motor Starter Output Assembly)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Fault Reset

Run

Instance 4 Data Format (Extended Contactor Output Assembly)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

RunRev

RunFwd

Instance 5 Data Format (Extended Motor Starter Output Assembly)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Fault Reset RunRev

RunFwd

Instance 20 Data Format (Basic Speed Control Output Assembly)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Fault Reset

RunFwd

1

2

1

Speed Reference RPM (Low Byte)

3

1

Speed Reference RPM (High Byte)

Instance 21 Data Format (Reversing Speed Control Output Assembly)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

NetRef

Net
Control

Fault Reset RunRev

RunFwd

1

2

1

Speed Reference RPM (Low Byte)

3

1

Speed Reference RPM (High Byte)

Instance 100 Data Format (Reversing Speed Control Output Assembly (Hz)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Fault Reset RunRev

RunFwd

1

2

1

Speed Ref Hz (0.1 Hz) (Low Byte)

2

3

1

Speed Ref Hz (0.1 Hz) (High Byte)

2