Rockwell Automation VSM500 Integrated Drive/Motor DeviceNet Option Board User Manual
Page 88

C-20
VSM500 DeviceNet Option Board
C.10 Class Code 0x29 – Control Supervisor Object
Class Attributes
Instance 1 Attributes
Attribute ID
Access Rule
Name
Data Type
Value
1
Get
Revision
UINT
1
2
Get
Max Instance
UINT
1
6
Get
Max ID Class
UINT
7
7
Get
Max ID Instance
UINT
17
Attribute
ID
Access
Rule
Name
Data
Type
Value
1
Get
Number of
Attributes
USINT
17
2
Get
Attributes
List
Array of
USINT
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16,
17
3
Get/Set
1
Run 1
BOOL
See Run/Stop Event Matrix on page C-22.
4
Get/
Set
1
Run 2
BOOL
See Run/Stop Event Matrix on page C-22.
5
Get/
Set
1
NetCtrl
BOOL
0 = TB or keypad control
1 = Network control
6
Get
State
USINT
3 = Ready
4 = Enabled
5 = Stopping
7 = Faulted
7
Get
Running 1
BOOL
0 = Not running forward
1 = Running forward
8
Get
Running 2
BOOL
0 = Not running reverse
1 = Running reverse
9
Get
Ready
BOOL
0 = Other state
1 = Ready or Enabled or Stopping
10
Get
Faulted
BOOL
0 = No faults present
1 = Fault occurred (latched)
11
Get
Warning
BOOL
0
12
Get/
Set
Fault Reset
BOOL
0 = No action
0 -> 1 = Fault Reset
1
This attribute can be set only when the expected packet rate (EPR) for the explicit connection is
non-zero and the VSM500 unit does not have an active I/O connection.