Rockwell Automation VSM500 Integrated Drive/Motor DeviceNet Option Board User Manual

Page 22

Advertising
background image

3-2

VSM500 DeviceNet Option Board

Step 3. Under Available DeviceNet Drivers, select a DeviceNet driver, and then click

OK. The Driver Configuration dialog box appears.

Step 4. Select the appropriate settings for the following:

Step 5. Click OK to go online. The online icon is displayed under Comm in the lower

right corner of the main window.

Figure 3.1 – DeviceNet Driver Selection Dialog Box

Figure 3.2 – Driver Configuration Dialog Box

Box

Description

Serial Port
Setup

Select the communications port on your computer to which the DeviceNet
adapter is connected.

Baud Rate

Select the baud rate that is used by your computer communications port.

Node
Address

Type a unique node address for the computer on the DeviceNet network.
Usually, computers use the node address 62. Do not use 63 because this is the
factory-default setting for new devices on the network.

Data Rate

Select the data rate that devices on the DeviceNet network are using.

Figure 3.3 – DeviceNet Manager in Online Mode Icon