B.2 parameter groups – Rockwell Automation VSM500 Integrated Drive/Motor DeviceNet Option Board User Manual

Page 60

Advertising
background image

B-2

VSM500 DeviceNet Option Board

B.2 Parameter Groups

Parameters in the VSM500 Integrated drive/motor are grouped into either the Display
group or the Program group. Parameters in the Display group are read only. You can
get their values, but you cannot change their values. Parameters in the Program group
are read/write. You can get and set their values. When a DeviceNet option board is
connected, its parameters are grouped in the DNet Config group. Its parameters are
also read/write. Figure B.1 illustrates the parameter groups of a VSM500 Integrated
drive/motor with a DeviceNet option board.

Table B.1 – Parameter Groups

Drive Display

Drive Program

DNet Config

01 - Command Frequency
02 - Output Frequency
03 - Output Voltage
04 - Output Current
05 - Load Current
06 - Bus Voltage
07 - Power Unit Temperature
08 - Analog Input
09 - TB Input Status
10 - Last Fault

30 - Minimum Frequency
31 - Maximum Frequency
32 - Accel Time
33 - Decel Time
34 - Start Source
35 - Run On Power Up
36 - Speed Ref Source
37 - Relay Control Output
38 - Auto Restart Attempts
39 - Auto Restart Delay
40 - Torque Curve
41 - Torque Boost
42 - Base Frequency
43 - Base Voltage
44 - Stop Select
45 - Reverse Disable
46 - IR Compensation
47 - Slip Compensation
48 - Analog Minimum
49 - Analog Maximum
50 - Fault Reset
51 - Preset Speed 1
52 - Preset Speed 2
53 - Preset Speed 3
54 - Preset Speed 4
55 - Preset Speed 5
56 - Preset Speed 6
57 - Preset Speed 7

101 - Switches MAC ID
102 - Switches Baud
103 - NV MAC ID
104 - NV Baud Rate
105 - Bus Off Error
106 - Bus Off Count
107 - Output Assembly
108 - Input Assembly
109 - DNet Fault Mode
110 - DNet Idle Mode
111 - DNet SW Mode
112 - COS Mask
113 - Reset