Synchronizing raid controller module clocks, Locating physical disks, Performance tuning – Dell PowerVault MD3000 User Manual

Page 95

Advertising
background image

Maintaining a Storage Array

95

To determine which virtual disks have reservations, run the following
command:

show (allVirtualDisks | virtualDisk

[

virtualDiskName

] | virtualDisks [

virtualDiskName1

... virtualDiskNamen

]) reservations

To clear persistent virtual disk reservations, run the following command:

clear (allVirtualDisks |

virtualDisk[

virtualDiskName

] | virtualDisks

[

virtualDiskName1

" ... "

virtualDiskNamen

])

reservations

Synchronizing RAID Controller Module Clocks

To synchronize the clocks on both RAID controller modules in a storage array
with the host clock, run the following command:

set storageArray time

Locating Physical Disks

At times, you might need to locate a specific physical disk. In very large
storage array configurations, this can sometimes be awkward. If you need to
locate a specific physical disk, turn on the indicator LED on the front of the
physical disk. To turn on the indicator LED on a physical disk, run the
following command:

start physicalDisk [

enclosureID,slotID

] blink

To turn off the indicator LED after locating the physical disk, run the
following command:

stop physicalDisk blink

Performance Tuning

Over time, as a storage array exchanges data between the hosts and physical
disks, its performance can degrade. Monitor the performance of a storage
array and make adjustments to the storage array operational settings to
improve performance.

Advertising