Monitoring performance – Dell PowerVault MD3000 User Manual

Page 96

Advertising
background image

96

Maintaining a Storage Array

Monitoring Performance

Monitor the performance of a storage array by using the save storageArray
performanceStats command. This command saves performance information
to a file that you can review to determine how well the storage array is
running. Table 6-1 lists the performance information saved to the file.

Table 6-1.

Storage Array Performance Information

Type of Information

Description

Devices

Devices are:

• RAID Controller Modules — The RAID controller module

in slot 0 or 1 and a list of the virtual disks owned by the
RAID controller module

• Virtual Disk — A list of the virtual disk names

• Storage Array Totals — A list of the totals for both RAID

controller modules in an active-active RAID controller
module pair, regardless if one, both, or neither are selected
for monitoring

Total I/Os

Number of total I/Os performed since the storage array was
started

Read Percentage

Percentage of total I/Os that are read operations (calculate
the write percentage by subtracting the read percentage from
100 percent)

Cache Hit Percentage Percentage of reads that are fulfilled by data from the cache

rather than requiring an actual read from a physical disk

Current KB/second

Current transfer rate in kilobytes per second (current means
the number of kilobytes per second since the last time the
polling interval elapsed, causing an update to occur)

Maximum KB/second Highest data transfer value achieved in the current

kilobyte-per-second statistic block

Current IO/second

Current number of I/Os per second (current means the
number of I/Os per second since the last time the polling
interval elapsed, causing an update to occur)

Maximum IO/second Highest number of I/Os achieved in the current

I/O-per-second statistic block