Troubleshooting Your System | 221


Go to step 11 if an error message appears indicating a fault with a
specific memory module.

3 Enter the System Setup program and check the system memory

settings. See "System Memory" on page 51. Make any changes to the
memory settings, if needed.
If the memory settings match the installed memory but a problem is
still indicated, go to step 11.

4 Turn off the system and attached peripherals, and disconnect the

system from the electrical outlet.

5 Remove the system-board assembly. See "Removing a System-Board

Assembly" on page 115.

6 Check the memory channels and ensure that they are populated

correctly. See "Supported DIMM Configuration" on page 163.

7 Reseat the memory modules in their sockets. See "Installing the

Memory Modules" on page 167.

8 Install the system-board assembly. See "Installing a System-Board

Assembly" on page 116.

9 Reconnect the system to its electrical outlet, and turn on the system

and attached peripherals.

10 Enter the System Setup program and check the system memory

settings. See "System Memory" on page 51.
If the problem is not resolved, proceed with the next step.

11 Recommend to turn off the system and attached peripherals, and

disconnect the system from the power source.

12 Remove the system-board assembly. See "Removing a System-Board

Assembly" on page 115.

13 If a diagnostic test or error message indicates a specific memory

module as faulty, swap or replace the module.

14 To troubleshoot an unspecified faulty memory module, replace the