About Your System | 27


Error Code Error Message

Error Cause

Recovery Method

0082h

Secondary Master

Drive-ATAPI
Incompatible

HDD/ATAPI/IDE device

failure

Change HDD

0083h

Secondary Slave Drive-
ATAPI Incompatible

HDD/ATAPI/IDE device
failure

Change HDD

0166h

CPU Frequency
mismatch!

CPU mix installed is not
support

Install same model
CPU

0167h

CPUID mismatch!

CPU mix installed is not
support

Install same model
CPU

0168h

L1 cache size mismatch! CPU mix installed is not

support

Install same model
CPU

0169h

L2 cache size mismatch! CPU mix installed is not

support

Install same model
CPU

016Ah

CPU Patch level
mismatch!

CPU mix installed is not
support

Install same model
CPU

4168h

DIMM CRC Error or be
ignore POST Error

DIMM bad

Change DIMM

4169h

DIMM Chip Select
Disable, Test Fail

DIMM bad

Change DIMM

5120h

CMOS cleared by
jumper

CMOS clear by jumper No action

5122h

Password cleared by

jumper

Password clear by jumper No action

8104h

Warning! Port 60h/64h
emulation is not
supported by this USB
Host Controller!!!

Not supported by the HC Board repair

8105h

Warning! EHCI
controller disabled. It
requires 64 bit data
support in the BIOS.

Check whether this host
controller needs 64 bit
data structure or not

Board repair

8601h

Error: BMC Not
Responding

BMC chip does not find Board repair

8701h

Insufficient Runtime
space for MPS data!!

System may operate in
PIC or Non-MPS mode.

Failed to copy the
MPTable to F000 or

E000 shadow RAM

Board repair

8702h

No enough APIC ID in Check APIC failed

Board repair