Troubleshooting Your System

161

11 Close the system. See "Closing the System" on page 79.
12 Turn on the system and attached peripherals and check if the SD card is

functioning.
If the problem is not resolved, see "Getting Help" on page 183.

Troubleshooting an Optical Drive

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in
your product documentation, or as directed by the online or telephone service
and support team. Damage due to servicing that is not authorized by Dell is
not covered by your warranty. Read and follow the safety instructions that
came with the product.

1 If applicable, remove the bezel. See "Removing the Front Bezel" on

page 77.

2 Try using a different CD or DVD.
3 Enter the System Setup program and ensure that the integrated SATA

controller and the drive's SATA port are enabled. See "Using the System

Setup Program and UEFI Boot Manager" on page 55.

4 Run the appropriate online diagnostic test. See "Using Online Diagnostics"

on page 169.

5 Turn off the system and attached peripherals, and disconnect the system

from the electrical outlet.

6 Open the system. See "Opening the System" on page 78.
7 Ensure that the interface cable is securely connected to the optical drive

and to the system board. See "Optical Drive" on page 85.

8 Ensure that a power cable is properly connected to the drive.
9 Close the system. See "Closing the System" on page 79.

10 Reconnect the system to the electrical outlet, and turn on the system and

attached peripherals.
If the problem is not resolved, see "Getting Help" on page 183.