24

About Your System

Table 1-1. LCD Status Messages

Code

Text

Causes

Corrective Actions

E1000 Failsafe

voltage

error.

Contact

support.

Check the system event log

for critical failure events.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 183.

E1114 Ambient Temp

exceeds

allowed

range.

Ambient temperature

reached a point outside the

allowed range.

See "Troubleshooting

System Cooling

Problems" on page 155.

E1116 Memory

disabled,

temp above

range. Power

cycle AC.

Memory exceeded allowable

temperature and has been

disabled to prevent damage

to the components.

Remove AC power to the

system for 10 seconds and

restart the system.
See "Troubleshooting

System Cooling

Problems" on page 155. If

the problem persists, see

"Getting Help" on

page 183.

E1119 Chipset #

temp out of

range. Check

motherboard

heatsinks.

Chipset temperature

reached a point outside the

allowed range.

See "Troubleshooting

System Cooling

Problems" on page 155.

E1210 Motherboard

battery

failure.

Check

battery.

CMOS battery is missing or

the voltage is outside the

allowable range.

See "Troubleshooting the

System Battery" on

page 154.

book.book Page 24 Thursday, June 3, 2010 4:35 PM