Dell PowerEdge R715 User Manual

Page 34

Advertising
background image

34

About Your System

E2010 Memory not

detected.

Inspect

DIMMs.

No memory detected in the

system.

Install memory or reseat

the memory modules. See

"Installing Memory

Modules" on page 95 or

"Troubleshooting System

Memory" on page 157.

E2011 Memory

configuration

failure.

Check DIMMs.

Memory detected, but is not

configurable. Error detected

during memory

configuration.

See "Troubleshooting

System Memory" on

page 157.

E2012 Memory

configured

but unusable.

Check DIMMs.

Memory configured, but is

unusable.

See "Troubleshooting

System Memory" on

page 157.

E2013 BIOS unable

to shadow

memory. Check

DIMMs.

The system BIOS failed to

copy its flash image into

memory.

See "Troubleshooting

System Memory" on

page 157.

E2014 CMOS RAM

failure.

Power cycle

AC.

CMOS failure. CMOS RAM

not functioning properly.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 183.

E2015 DMA

Controller

failure.

Power cycle

AC.

DMA controller failure.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 183.

E2016 Interrupt

Controller

failure.

Power cycle

AC.

Interrupt controller failure. Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 183.

Code

Text

Causes

Corrective Actions

book.book Page 34 Thursday, June 3, 2010 4:35 PM

Advertising