Dell PowerEdge R715 User Manual

Page 50

Advertising
background image

50

About Your System

Warning! Power

required exceeds

PSU wattage.

Check PSU and

system

configuration.

Warning!

Performance

degraded. CPU and

memory set to

minimum

frequencies to

meet PSU wattage.

System will

reboot.

The system configuration of

processor(s), memory

modules, and expansion

cards may not be supported

by the power supplies.

If any system components

were just upgraded, return

the system to the previous

configuration. If the system

boots without this warning,

then the replaced

component(s) are not

supported with this power

supply. If low wattage power

supplies are installed, replace

them with High Output

power supplies to use the

components. See "Power

Supplies" on page 87.

Write fault.

Write fault on

selected drive.

Faulty USB device, USB

medium, optical drive

assembly, hard drive, or hard-

drive subsystem.

Replace the USB medium or

device. Ensure that the USB,

SAS backplane, or SATA

cables are properly

connected. See

"Troubleshooting a USB

Device" on page 150,

"Troubleshooting an Internal

USB Key" on page 159, and

"Troubleshooting a Hard

Drive" on page 162.

Incorrect memory

configuration

CPU n.

The DIMM group for CPU n

is incorrectly configured and

caused the system to halt.

See "General Memory

Module Installation

Guidelines" on page 92, for

memory configuration

information. If the problem

persists, see

"Troubleshooting System

Memory" on page 157.

Message

Causes

Corrective Actions

book.book Page 50 Thursday, June 3, 2010 4:35 PM

Advertising