Dell PowerEdge R715 User Manual

Page 27

Advertising
background image

About Your System

27

E1418 CPU # not

detected.

Check CPU is

seated

properly.

Specified processor is

missing or bad and the

system is in an unsupported

configuration.

Ensure that the specified

processor is properly

installed. See

"Troubleshooting the

Processors" on page 166.

E141C Unsupported

CPU

configuration

. Check CPU

or BIOS

revision.

Processors are in an

unsupported configuration.

Ensure that your

processors match and

conform to the type

described in the processor

technical specifications

outlined in your system’s

Getting Started Guide.

E141F CPU #

protocol

error. Power

cycle AC.

The system BIOS reported a

processor protocol error.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 183.

E1420 CPU Bus

parity error.

Power cycle

AC.

The system BIOS reported a

processor bus parity error.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 183.

E1421 CPU #

initialization

error. Power

cycle AC.

The system BIOS reported a

processor initialization error.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 183.

E1422 CPU # machine

check error.

Power cycle

AC.

The system BIOS reported a

machine check error.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 183.

Code

Text

Causes

Corrective Actions

book.book Page 27 Thursday, June 3, 2010 4:35 PM